TABLE 1B. TURFGRASS QUALITY AND OTHER RATINGS OF ALL CULTIVARS WITH 65% OF ET IN THE 2022 NATIONAL COOL-SEASON WATER USE/DROUGHT TOLERANCE TEST AT FORT COLLINS, CO 1/ 2024 DATA TURFGRASS QUALITY AND OTHER RATINGS 1-9; 9=BEST 2/ WINTER GREENUP GREENUP LEAF SUMMER PRE-DROUGHT COVERAGE QUALITY RATINGS NAME COLOR 3/6 4/3 TEXTURE DENSITY 3/6 5/22 5/27 PPG FRC 127 FF 2.3 4.0 5.7 7.3 8.3 99.0 94.3 98.7 COMPASS II FF 2.0 4.0 5.3 8.3 8.0 98.3 97.3 99.0 PENNCROSS BT 1.0 1.0 2.7 4.7 7.0 71.0 96.3 98.7 NAVIGATOR II FF 2.0 4.7 6.7 8.0 8.0 99.0 93.7 92.7 OAKLEY BT 1.0 1.0 2.3 5.7 7.3 70.7 95.7 99.0 GLADIATOR FF 2.0 3.7 4.7 8.0 7.3 99.0 97.3 75.7 KINGDOM BT 1.0 1.0 2.7 6.7 7.3 49.3 98.7 99.0 PIRANHA BT 1.0 1.0 2.3 7.0 7.7 67.7 98.0 99.0 DLF-AP-3084 BT 1.0 1.0 2.7 6.3 7.7 61.0 98.7 99.0 T-1 BT 1.0 1.0 2.7 5.0 7.0 64.3 95.7 99.0 PIPER BT 1.0 1.0 2.0 5.7 7.0 65.3 90.7 99.0 007XL BT 1.0 1.0 3.0 6.0 6.7 64.3 88.7 99.0 AU VICTORY BT 1.0 1.0 2.3 5.3 7.3 58.7 97.0 99.0 HELIOS PR 1.3 2.3 4.0 5.3 6.3 92.7 91.7 95.3 777 BT 1.0 1.0 2.0 5.7 7.0 64.3 89.3 99.0 MACDONALD BT 1.0 1.0 2.7 6.0 7.0 64.7 98.3 99.0 SR 4650 PR 1.3 2.3 4.3 4.7 6.3 72.7 87.7 94.3 MUSKET BT 1.0 1.0 3.0 6.0 7.0 . . . LSD VALUE 1.3 0.8 0.8 2.3 1.5 24.0 24.9 20.2 C.V. (%) 42.9 25.7 14.2 18.3 9.2 18.6 8.2 8.5 1/ TO DETERMINE STATISTICAL DIFFERENCES AMONG ENTRIES, SUBTRACT ONE ENTRY'S MEAN FROM ANOTHER ENTRY'S MEAN. STATISTICAL DIFFERENCES OCCUR WHEN THIS VALUE IS LARGER THAN THE CORRESPONDING LSD VALUE (LSD 0.05). 2/ C.V. (COEFFICIENT OF VARIATION) INDICATES THE PERCENT VARIATION OF THE MEAN IN EACH COLUMN. TABLE 1B. TURFGRASS QUALITY AND OTHER RATINGS OF ALL CULTIVARS WITH 65% OF ET (CONT'D) IN THE 2022 NATIONAL COOL-SEASON WATER USE/DROUGHT TOLERANCE TEST AT FORT COLLINS, CO 1/ 2024 DATA TURFGRASS QUALITY AND OTHER RATINGS 1-9; 9=BEST 2/ DROUGHT STRESS RATINGS JUNE-SEPTEMBER NAME 6/10 6/21 6/28 7/5 7/12 7/20 7/31 8/16 8/22 8/30 9/9 PPG FRC 127 FF 6.7 3.0 4.7 5.0 3.7 4.0 6.3 7.7 5.0 6.0 7.3 COMPASS II FF 5.3 3.0 5.3 4.3 4.7 4.0 6.3 8.0 5.3 6.0 6.7 PENNCROSS BT 9.0 7.0 6.7 6.0 5.3 5.3 7.3 8.0 4.3 7.3 8.0 NAVIGATOR II FF 4.7 2.7 3.7 4.3 3.3 4.0 6.0 7.3 4.7 6.7 6.7 OAKLEY BT 9.0 7.3 6.3 5.3 5.3 5.7 7.0 8.7 6.7 7.0 8.0 GLADIATOR FF 6.0 3.0 5.7 5.0 4.7 4.0 6.3 8.0 4.3 6.0 6.7 KINGDOM BT 9.0 7.3 6.0 6.0 5.7 6.7 7.7 8.0 5.0 7.0 7.3 PIRANHA BT 9.0 7.0 6.7 5.7 5.7 5.3 7.0 8.0 5.7 7.0 7.7 DLF-AP-3084 BT 9.0 7.0 7.0 6.0 6.0 6.0 7.3 8.0 5.7 7.3 8.0 T-1 BT 9.0 7.0 7.0 5.7 4.7 6.0 7.3 8.0 5.0 7.3 7.7 PIPER BT 9.0 6.7 6.7 5.7 5.0 6.0 7.0 8.3 5.3 7.3 8.0 007XL BT 9.0 7.3 6.0 5.0 5.3 5.0 6.0 8.0 4.3 7.3 7.7 AU VICTORY BT 9.0 6.7 6.0 5.3 5.0 5.7 7.3 8.0 4.7 7.0 8.0 HELIOS PR 8.0 3.3 5.3 5.3 3.7 4.0 6.0 7.3 6.3 6.0 7.0 777 BT 9.0 6.7 6.7 5.3 5.0 6.0 6.7 8.3 6.0 7.3 7.3 MACDONALD BT 9.0 7.0 6.0 5.7 5.3 6.0 7.3 7.7 5.0 7.0 7.7 SR 4650 PR 8.0 3.7 4.7 5.3 3.7 4.3 6.0 7.3 7.3 6.0 7.0 MUSKET BT 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 LSD VALUE 0.9 0.9 1.2 1.5 1.5 1.6 1.3 0.7 1.7 1.1 0.8 C.V. (%) 7.4 11.3 13.6 16.4 18.9 18.8 12.3 5.8 18.7 10.6 7.6 1/ TO DETERMINE STATISTICAL DIFFERENCES AMONG ENTRIES, SUBTRACT ONE ENTRY'S MEAN FROM ANOTHER ENTRY'S MEAN. STATISTICAL DIFFERENCES OCCUR WHEN THIS VALUE IS LARGER THAN THE CORRESPONDING LSD VALUE (LSD 0.05). 2/ C.V. (COEFFICIENT OF VARIATION) INDICATES THE PERCENT VARIATION OF THE MEAN IN EACH COLUMN. TABLE 1B. TURFGRASS QUALITY AND OTHER RATINGS OF ALL CULTIVARS WITH 65% OF ET (CONT'D) IN THE 2022 NATIONAL COOL-SEASON WATER USE/DROUGHT TOLERANCE TEST AT FORT COLLINS, CO 1/ 2024 DATA TURFGRASS QUALITY AND OTHER RATINGS 1-9; 9=BEST 2/ CANOPY TEMPERATURE DURING DROUGHT NAME 6/6 6/21 6/28 7/5 7/31 8/16 8/30 9/9 PPG FRC 127 FF 94.7 106.0 100.3 98.0 97.0 94.0 88.0 95.7 COMPASS II FF 93.3 105.7 101.0 97.0 98.7 95.0 88.0 95.3 PENNCROSS BT 94.7 99.3 98.3 98.7 99.3 94.0 88.7 92.7 NAVIGATOR II FF 99.0 111.7 105.0 103.3 105.0 95.7 88.7 94.3 OAKLEY BT 104.0 102.3 105.0 91.3 97.3 93.0 86.7 92.7 GLADIATOR FF 96.7 109.7 101.3 100.0 107.0 94.0 93.0 96.7 KINGDOM BT 105.0 103.7 99.0 95.0 95.0 93.7 88.7 91.7 PIRANHA BT 98.3 100.3 101.3 95.7 97.0 92.7 87.7 95.7 DLF-AP-3084 BT 96.0 98.7 94.3 94.0 94.3 92.7 87.0 93.0 T-1 BT 95.3 98.7 96.7 89.3 96.7 94.0 85.3 92.0 PIPER BT 97.7 97.3 97.3 89.3 94.3 88.7 88.0 93.0 007XL BT 97.3 99.3 102.7 88.0 94.3 91.5 89.0 94.7 AU VICTORY BT 101.0 106.3 102.7 92.7 96.3 92.3 90.0 94.0 HELIOS PR 96.0 107.0 106.0 96.0 100.0 92.0 89.3 93.3 777 BT 97.0 105.7 97.3 93.7 93.7 93.0 86.0 93.0 MACDONALD BT 100.0 98.7 102.0 92.7 99.0 94.7 87.3 92.3 SR 4650 PR 92.7 104.0 99.0 95.7 100.7 94.0 87.3 92.0 MUSKET BT . . . . . . . . LSD VALUE 23.6 10.2 10.3 11.4 7.5 10.9 4.8 3.8 C.V. (%) 7.5 4.8 4.3 5.4 4.0 3.6 2.5 1.9 1/ TO DETERMINE STATISTICAL DIFFERENCES AMONG ENTRIES, SUBTRACT ONE ENTRY'S MEAN FROM ANOTHER ENTRY'S MEAN. STATISTICAL DIFFERENCES OCCUR WHEN THIS VALUE IS LARGER THAN THE CORRESPONDING LSD VALUE (LSD 0.05). 2/ C.V. (COEFFICIENT OF VARIATION) INDICATES THE PERCENT VARIATION OF THE MEAN IN EACH COLUMN. TABLE 1B. TURFGRASS QUALITY AND OTHER RATINGS OF ALL CULTIVARS WITH 65% OF ET (CONT'D) IN THE 2022 NATIONAL COOL-SEASON WATER USE/DROUGHT TOLERANCE TEST AT FORT COLLINS, CO 1/ 2024 DATA TURFGRASS QUALITY AND OTHER RATINGS 1-9; 9=BEST 2/ QUALITY PRE-DROUGHT QUALITY DURING DROUGHT JUNE-SEPTEMBER NAME 3/6 5/22 5/27 6/5 6/10 6/21 6/28 7/12 PPG FRC 127 FF 3.0 7.7 7.7 6.3 4.0 3.0 4.0 3.3 COMPASS II FF 3.7 6.3 6.3 6.0 4.3 2.3 4.0 3.7 PENNCROSS BT 1.0 4.3 4.3 4.3 4.0 3.7 4.0 5.0 NAVIGATOR II FF 3.3 7.7 7.7 6.7 4.0 3.0 4.0 3.3 OAKLEY BT 1.0 4.7 4.7 4.0 4.0 3.7 4.0 4.0 GLADIATOR FF 3.3 7.0 7.0 6.0 4.3 3.0 4.3 4.3 KINGDOM BT 1.0 4.7 4.7 3.0 4.3 3.3 3.7 5.7 PIRANHA BT 1.0 4.3 4.3 3.7 4.0 3.3 4.3 4.3 DLF-AP-3084 BT 1.0 4.3 4.3 3.0 3.3 3.3 3.7 5.7 T-1 BT 1.0 4.3 4.3 3.3 3.3 3.7 3.0 4.3 PIPER BT 1.0 4.3 4.3 3.3 3.3 3.0 3.0 4.7 007XL BT 1.0 4.7 4.7 4.0 3.3 3.0 3.7 4.3 AU VICTORY BT 1.0 4.0 4.0 3.0 3.0 2.7 3.0 4.3 HELIOS PR 2.0 5.0 5.0 4.7 4.0 3.0 4.0 3.0 777 BT 1.0 4.3 4.3 3.3 3.0 3.0 3.7 4.7 MACDONALD BT 1.0 4.0 4.0 3.3 3.0 2.7 3.0 4.7 SR 4650 PR 2.0 5.0 5.0 4.7 4.0 2.3 4.0 3.0 MUSKET BT 2.0 3.0 2.0 2.0 2.0 2.0 2.0 2.0 LSD VALUE 0.3 1.0 0.7 1.3 1.6 2.4 2.2 1.4 C.V. (%) 13.4 12.6 9.7 19.8 20.6 27.1 23.9 19.6 1/ TO DETERMINE STATISTICAL DIFFERENCES AMONG ENTRIES, SUBTRACT ONE ENTRY'S MEAN FROM ANOTHER ENTRY'S MEAN. STATISTICAL DIFFERENCES OCCUR WHEN THIS VALUE IS LARGER THAN THE CORRESPONDING LSD VALUE (LSD 0.05). 2/ C.V. (COEFFICIENT OF VARIATION) INDICATES THE PERCENT VARIATION OF THE MEAN IN EACH COLUMN. TABLE 1B. TURFGRASS QUALITY AND OTHER RATINGS OF ALL CULTIVARS WITH 65% OF ET (CONT'D) IN THE 2022 NATIONAL COOL-SEASON WATER USE/DROUGHT TOLERANCE TEST AT FORT COLLINS, CO 1/ 2024 DATA TURFGRASS QUALITY AND OTHER RATINGS 1-9; 9=BEST 2/ QUALITY RATINGS DURING DROUGHT JULY-SEPTEMBER QUALITY RATINGS DURING RECOVERY NAME 7/20 7/31 8/16 8/30 9/9 9/30 10/8 10/16 MEAN PPG FRC 127 FF 4.7 4.0 4.3 5.0 5.3 5.7 6.0 5.3 5.0 COMPASS II FF 4.3 4.0 5.0 5.7 5.7 5.3 6.0 5.3 4.9 PENNCROSS BT 5.3 4.3 5.7 6.0 6.7 6.3 7.0 6.0 4.9 NAVIGATOR II FF 4.3 4.0 4.0 4.7 4.3 5.7 5.0 4.3 4.8 OAKLEY BT 5.0 4.7 6.0 5.7 6.0 6.7 6.0 6.3 4.8 GLADIATOR FF 4.0 4.0 4.3 4.7 4.3 4.7 4.7 4.3 4.6 KINGDOM BT 5.0 5.0 5.3 5.3 5.3 5.7 6.0 5.7 4.6 PIRANHA BT 4.7 4.7 5.3 5.7 5.3 6.3 6.0 6.0 4.6 DLF-AP-3084 BT 4.3 4.7 5.0 6.0 6.0 6.0 6.3 5.7 4.5 T-1 BT 4.3 4.3 5.3 5.7 5.3 6.3 6.7 6.3 4.5 PIPER BT 4.3 4.0 5.0 5.7 5.3 6.0 6.3 6.0 4.4 007XL BT 4.0 3.7 5.0 5.7 5.0 5.7 6.0 5.3 4.3 AU VICTORY BT 5.0 4.3 5.0 5.3 6.0 5.7 6.0 5.7 4.3 HELIOS PR 3.7 4.0 4.3 4.3 4.3 6.0 5.7 5.3 4.3 777 BT 4.0 4.0 4.7 5.3 4.7 5.7 5.7 5.7 4.2 MACDONALD BT 4.0 4.7 4.7 4.7 5.3 6.3 6.0 5.7 4.2 SR 4650 PR 3.7 4.0 4.3 4.3 4.7 5.3 5.3 5.0 4.2 MUSKET BT 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.1 LSD VALUE 1.8 2.1 1.0 1.3 1.4 1.3 1.0 1.1 0.6 C.V. (%) 20.3 21.4 12.9 14.7 15.8 13.7 10.7 13.0 8.7 1/ TO DETERMINE STATISTICAL DIFFERENCES AMONG ENTRIES, SUBTRACT ONE ENTRY'S MEAN FROM ANOTHER ENTRY'S MEAN. STATISTICAL DIFFERENCES OCCUR WHEN THIS VALUE IS LARGER THAN THE CORRESPONDING LSD VALUE (LSD 0.05). 2/ C.V. (COEFFICIENT OF VARIATION) INDICATES THE PERCENT VARIATION OF THE MEAN IN EACH COLUMN.