TABLE 3. MEAN TURFGRASS QUALITY AND OTHER RATINGS OF BERMUDAGRASS CULTIVARS IN THE 2007 NATIONAL BERMUDAGRASS TEST AT BATON ROUGE, LA 1/ 2007 DATA TURFGRASS QUALITY AND OTHER RATINGS 1-9; 9=BEST 2/ GENETIC LEAF DENSITY PERCENT ESTABLISHMENT QUALITY RATINGS NAME COLOR TEXTURE FALL 4-WEEKS 10-WEEKS AUG SEP OCT NOV DEC MEAN OKC 1119 6.0 7.7 7.7 16.7 97.7 6.0 7.0 7.7 7.0 7.0 6.9 PREMIER 7.3 7.3 7.7 25.0 99.0 6.7 6.7 7.3 7.0 6.3 6.8 PRINCESS 77 6.3 5.7 6.7 16.7 99.0 6.0 7.0 7.0 6.7 6.7 6.7 OKS 2004-2 6.3 6.7 7.0 16.7 99.0 6.3 6.7 7.0 7.0 6.0 6.6 SWI-1083 6.0 5.7 7.0 35.0 97.7 6.3 6.7 7.0 7.0 6.0 6.6 TIFWAY 7.0 7.0 6.7 15.0 91.3 6.0 6.7 7.0 6.7 6.3 6.5 RIVIERA 6.3 5.7 7.0 25.0 97.7 6.0 6.7 6.7 6.7 6.0 6.4 SWI-1117 6.3 5.7 7.0 36.7 99.0 6.0 6.3 6.3 6.3 6.0 6.2 HOLLYWOOD (J-720) 6.3 6.0 7.0 30.0 99.0 5.7 5.7 6.3 6.3 6.3 6.1 OKC 1134 6.7 7.0 7.3 33.3 99.0 5.3 5.3 7.0 6.7 6.0 6.1 PSG 9BAN 6.3 5.7 6.7 26.7 99.0 6.0 6.0 6.3 6.3 5.7 6.1 RAD-CD1 5.7 5.7 6.7 23.3 99.0 6.0 6.0 6.3 6.3 6.0 6.1 SWI-1070 6.3 5.7 7.0 36.7 99.0 5.7 6.0 6.3 6.3 6.3 6.1 SWI-1081 6.0 5.7 6.7 21.7 97.7 5.3 6.0 6.3 6.3 6.3 6.1 PYRAMID 2 (IS-CD10)6.3 5.3 6.7 21.7 99.0 6.0 6.0 6.0 6.0 6.0 6.0 IS-01-201 5.7 6.0 7.0 20.0 97.7 5.3 5.7 6.3 6.3 5.7 5.9 SUNSPORT 6.0 6.0 7.0 46.7 99.0 6.3 5.7 6.0 6.0 5.3 5.9 PSG 91215 6.3 5.7 6.7 23.3 96.3 6.0 6.0 5.7 5.7 5.3 5.7 PSG PROK 6.7 5.0 6.7 36.7 99.0 6.0 5.7 6.0 5.7 5.3 5.7 PST-R6FLT 6.3 6.0 6.3 10.0 97.7 5.3 5.3 6.0 6.0 6.0 5.7 SWI-1113 6.3 5.7 6.3 20.0 96.3 5.7 5.7 5.7 6.0 5.7 5.7 SWI-1122 6.7 5.7 6.3 23.3 97.7 5.3 5.0 6.0 6.0 5.7 5.6 PSG 94524 6.0 5.0 6.3 35.0 99.0 5.3 5.3 5.7 5.7 5.3 5.5 PSG 9Y2OK 6.0 5.7 6.3 28.3 97.7 5.0 5.0 6.0 6.0 5.3 5.5 SWI-1057 6.3 5.3 5.7 18.3 99.0 5.0 5.0 5.7 5.7 5.7 5.4 PATRIOT 7.0 5.7 6.3 21.7 95.0 4.3 4.7 5.7 6.0 6.0 5.3 YUKON 6.3 5.0 5.0 15.0 93.0 4.7 5.3 5.3 5.7 5.3 5.3 BAR 7CD5 5.7 5.0 5.3 13.3 93.0 4.3 5.0 5.7 5.3 5.3 5.1 MIDLAWN 5.7 6.0 5.7 15.0 93.3 4.3 4.3 5.3 5.7 5.7 5.1 NUMEX-SAHARA 6.3 4.0 5.0 53.3 97.7 5.0 5.0 5.0 5.3 5.3 5.1 VERACRUZ 6.0 5.7 6.0 15.0 99.0 4.7 4.7 5.0 5.0 5.0 4.9 LSD VALUE 1.4 0.9 1.1 17.7 6.6 1.1 1.0 1.2 1.1 1.4 0.8 C.V. (%) 8.8 9.2 9.4 39.6 2.9 11.0 10.8 10.7 9.2 10.4 7.7 1/ TO DETERMINE STATISTICAL DIFFERENCES AMONG ENTRIES, SUBTRACT ONE ENTRY'S MEAN FROM ANOTHER ENTRY'S MEAN. STATISTICAL DIFFERENCES OCCUR WHEN THIS VALUE IS LARGER THAN THE CORRESPONDING LSD VALUE (LSD 0.05). 2/ C.V. (COEFFICIENT OF VARIATION) INDICATES THE PERCENT VARIATION OF THE MEAN IN EACH COLUMN. TABLE A. 2007 LOCATIONS, SITE DESCRIPTIONS AND MANAGEMENT PRACTICES IN THE 2007 NATIONAL BERMUDAGRASS TEST SOIL SOIL SUN MOWING SOIL SOIL PHOSPHOROUS POTASSIUM NITROGEN OR HEIGHT IRRIGATION LOCATION TEXTURE PH (LBS/ACRE) (LBS/ACRE) (LBS/1000 SQ FT) SHADE (IN) PRACTICED LA1 SILTY CLAY AND CLAY 6.1-6.5 151-270 241-375 4.1-5.0 FULL SUN 0.6-1.0 TO PREVENT STRESS